EN
TR   
Core Numbers x Conductor Section (mm²)O.D. Approx (mm²)Copper Factor (kg/km)Cable Weight Approx (kg/km)
2 x 0,756,214,454,4
3 x 0,756,621,666,0
4 x 0,757,629,086,2
2 x 16,619,263,4
3 x 17,429,084,2
4 x 18,038,4101,2
2 x 1,57,429,082,7
3 x 1,57,943,0101,8
Core Numbers x Conductor Section (mm²)O.D. Approx (mm²)Copper Factor (kg/km)Cable Weight Approx (kg/km)
4 x 1,58,558,0123,5
2 x 2,59,148,0127,1
3 x 2,59,772,0157,0
4 x 2,510,596,0191,0
2 x 410,677,0181,3
3 x 411,3115,0227,5
4 x 412,6154,0296,2
CABLE CONSTRUCTION
ConductorStranded Bare Copper Wires ( HD 383 Class 5)
InsulationSilicone Compound (HD 22.1 S4 I El2)
Core IdentificationColor Coded Or Number Printed (DIN VDE 0293-308)
SheathSilicone Compound (HD 22.1 S4 I EM9)
ColorTile Red
APPLIED TESTS
Structural Dimension Tests HD 22.1,2
Mechanical TestsEN 60811-1-1, 1-2, 2-1
Electrical TestsHD 22.2
Low Temperature TestsEN 60811-1-4
Fire Performance TestsIEC 61031-1, IEC 60332-1-2, IEC 60754-1-2