APPLICATIONS

Radio and radio transmitters, radio receiver connections, electronic laboratory device connections and high It is used in frequency digital applications. Very high shielding is achieved thanks to two layers of silver braiding. Thanks to the silver-coated inner conductor, the signals are transmitted with the least loss.

CABLE CONSTRUCTION  
Conductor Silver Plated Copper Wire 7×0,76mm
Insulation PE
1.Screen Silver Plated Copper Wire Braid
2.Screen Silver Plated Copper Wire Braid
Outer Sheath PVC – RAL 9011 Black
ELECTRICAL PARAMETERS  
Capacitance 101 ± 2 pF/m
Impedance 50 ± 3 Ω
Spreading Speed %66 ± 2
Insulation Resistance 10000MΩ x km
Working Temperature -40 °C … +70 °C
Minimum Bending Radius 15 x D
ATTENUATION 20C° Max  
100 MHz 7 dB/100m
200 MHz 10.5 dB/100m
300 MHz  
400 MHz 15 dB/100m
500 MHz  
600 MHz 20 dB/100m
700 MHz  
800 MHz 23.50 dB/100m
900 MHz  
1000 MHz 28.00 dB/100m