APPLICATIONS
IP video and control, general purpose RS-232, RS-485 data and control general purpose communication and control systems.
| POWER CABLES | |
|---|---|
| Conductor | IEC 60228; DIN VDE 0295; EN 60228 Class 5 Stranded Electrolytic Annealed Copper |
| Insulation | PE |
| Insulation Color | Red – Black |
| Stranding | In Layers at Appropriate Steps |
| DATA CABLES (RS-422 / RS-485) | |
|---|---|
| Conductor | IEC 60228; DIN VDE 0295; EN 60228 Class 5 Stranded Electrolytic Tinned Annealed Copper |
| Insulation | FOAM PE |
| Insulation Color | Blue – White |
| Stranding | In Layers at Appropriate Steps |
| Separator Tape | Pes Tape |
| Screen | Tinned Copper Drain Wire + Al-Pes Tape |
| Sheath Color | UV RESISTANT WHITE HFFR |
COMMONLY USED STRUCTURE
2 x 2.5mm² +(1x2x0.22mm²) PIMF
2 x 1.5mm² +
(
1x2x0.22mm²) PIMF 2
| ELECTRICAL PARAMETERS | |
|---|---|
| Test Voltage | 0.22 and 0.34 mm² = 1200 V ≥ 0.50 mm² = 2000 V |
| Bend Radius | 10x Cable Ø |
| Working Temperature | -30ºC to +70ºC |
| Flame Retardancy Test | IEC 60332-1-2 DIN EN 60332-1-2 EN 60332-1-2 |
| EMC* | ELECTROMAGNETIC COMPATIBILITY |
| Conductor Resistance | 0.22mm²=79Ω/km – 0.34mm²=56Ω/km 0.50mm²=39Ω/km – 0.75mm²=26Ω/km 1.0mm²=19.5Ω/km – 1.5mm²=13.3Ω/km – 2.5mm²=7.98Ω/km |
| Insulation Resistance | MΩxKm 0.22 and 0.34 mm² = 200 ≥ 0.50 mm² = 20 |
| Effective Capacity | mm² 0.22 0.34 0.50 0.75 1.0 1.5 2.5 = pf/m 48 |
| Impedance | 78Ω |
| Inductance | 0.67 mH/km |
| Current Carrying Capacity | mm² 0.22=2.5A – 0.34=4.5A – 0.50=6.0A – 0.75=13A – 1.0=16A – 1.5=20A – 2.5=25A |
| Working Voltage | 0.22 and 0.34 mm² = 250 V ≥ 0.50 mm² = 300/500 V |
| FLAME RETARDANT TEST |
|---|
| IEC 60332-1-2 |
| VDE 0482-332-1-2 |
| EN 60332-1-2 |
| SMOKE DENSITY TEST |
|---|
| IEC 61034-2 |
| VDE 0482-1034-2 |
| EN 61034-2 |
| CORROSIVE GAS TEST |
|---|
| IEC 60754-2 |
| VDE 0482-754-2 |
| EN 60754-2 |