APPLICATIONS

IP video and control, general purpose RS-232, RS-485 data and control general purpose communication and control systems.

POWER CABLES  
Conductor IEC 60228; DIN VDE 0295; EN 60228 Class 5 Stranded Electrolytic Annealed Copper
Insulation PE
Insulation Color Red – Black
Stranding In Layers at Appropriate Steps
DATA CABLES (RS-422 / RS-485)  
Conductor IEC 60228; DIN VDE 0295; EN 60228 Class 5 Stranded Electrolytic Tinned Annealed Copper
Insulation FOAM PE
Insulation Color Blue – White
Stranding In Layers at Appropriate Steps
Separator Tape Pes Tape
Screen Tinned Copper Drain Wire + Al-Pes Tape
Sheath Color UV RESISTANT WHITE HFFR
COMMONLY USED STRUCTURE

2 x 2.5mm² +(1x2x0.22mm²) PIMF
2 x 1.5mm² +
(
1x2x0.22mm²) PIMF 2

ELECTRICAL PARAMETERS  
Test Voltage 0.22 and 0.34 mm² = 1200 V ≥ 0.50 mm² = 2000 V
Bend Radius 10x Cable Ø
Working Temperature -30ºC to +70ºC
Flame Retardancy Test IEC 60332-1-2 DIN EN 60332-1-2 EN 60332-1-2
EMC* ELECTROMAGNETIC COMPATIBILITY
Conductor Resistance 0.22mm²=79Ω/km – 0.34mm²=56Ω/km
0.50mm²=39Ω/km – 0.75mm²=26Ω/km
1.0mm²=19.5Ω/km – 1.5mm²=13.3Ω/km – 2.5mm²=7.98Ω/km
Insulation Resistance MΩxKm 0.22 and 0.34 mm² = 200 ≥ 0.50 mm² = 20
Effective Capacity mm² 0.22 0.34 0.50 0.75 1.0 1.5 2.5 = pf/m 48
Impedance 78Ω
Inductance 0.67 mH/km
Current Carrying Capacity mm² 0.22=2.5A – 0.34=4.5A – 0.50=6.0A – 0.75=13A – 1.0=16A – 1.5=20A – 2.5=25A
Working Voltage 0.22 and 0.34 mm² = 250 V ≥ 0.50 mm² = 300/500 V

 

FLAME RETARDANT TEST
IEC 60332-1-2
VDE 0482-332-1-2
EN 60332-1-2
SMOKE DENSITY TEST
IEC 61034-2
VDE 0482-1034-2
EN 61034-2
CORROSIVE GAS TEST
IEC 60754-2
VDE 0482-754-2
EN 60754-2