PROFIBUS DP
APPLICATIONS
These are the cables used in Scada systems, water and natural gas distribution networks, electricity production and distribution, fuel filling facilities, power plants and production lines.
CABLE CONSTRUCTION | |
---|---|
Conductor | Annealed Copper Wire 22 AWG |
Insulation | Foam PE |
Insulation Colours | A Wire Green – B Wire Red |
Filling | Polyvinyl Chloride (PVC) / HFFR |
1. Screen | AL-PES Tape |
2. Screen | Tinned Copper Braiding (Min 85% Closure) |
Sheath | Polyvinyl Chloride (PVC) / HFFR |
Sheath Color | RAL 4001 Purple |
Packing | 500 – 1000 mt |
INFORMATION TRANSMISSION SPEED |
---|
Frequency (MHz) |
---|
0.0096 |
0.0384 |
4.0 |
16.0 |
20.0 |
Attenuation (dB/100m) |
---|
2.5/100m |
4.0/100m |
22.0/100m |
42.0/100m |
45.0/100m |
Impedance (Ohm) |
---|
250 ± 25 |
185 ± 18 |
150 ± 15 |
150 ± 15 |
150 ± 15 |
ELECTRICAL PARAMETERS | |
---|---|
Max. Operating Voltage | 125 V |
Capacitance | 30 nF/km |
Max. Dc Conductor Resistance | 57 Ω/km (20˚C) |
Min. Insulation Resistance | 20°C Min. 5G Ω x km |
Nominal Loop Resistance | 115 Ω/km |
Test Tension | 1000V |
Impedance 10MHz | 20 mΩ/m |
Operating Temperature | -30°C to 80°C |
Min. Bending Radius | 6 x OD |
Maxi. Pulling Tension | 100 N |