APPLICATIONS

Cables with a rated impedance of 50 ohms comply with MIL-C-17 and are used in radio and wireless communications, RFID, WiFi, Distributed antenna systems (DAS), Wireless Internet (WISP), Global positioning (GPS) systems, defence industry and telecommunication systems. Cables with polyethylene sheath are preferable in outdoor and underground installations while the halogen-free version is mainly intended for areas that require fire resistance.

CABLE CONSTRUCTION
ConductorTwisted Electrolytic Copper Wire, 7×0,75mm (AWG13)Class 2, IEC 60228
InsulationLDPE, Ø 7,25mm 70°C,
ScreenElectrolytic Copper Wire Mesh, 95% Closure
Outer Sheath PVC – RAL 9011 Black, Ø 10,3mm TM51 70°C, EN 50290-2-22
Standard Length 100 – 300 – 500 mt
Product TypesRG213 U
ELECTRICAL PARAMETERS
Capacitance101 ± 2 pF/m
Impedance50 ± 3 Ω
Velocity%66 ± 2
Insulation Resistance 2 GΩxkm
Working Temperature-30 °C … +70 °C
Min. Bending Radius10 x D
ATTENUATION
1 MHz0,81 dB/100m
10 MHz2,09 dB/100m
50 MHz4,64 dB/100m
100 MHz6,75 dB/100m
200 MHz10,03 dB/100m
400 MHz15,25 dB/100m
700 MHz21,80 dB/100m
900 MHz25,75 dB/100m
1000 MHz27,64 dB/100m